Review




Structured Review

Fisher Scientific lc grade acetonitrile
Lc Grade Acetonitrile, supplied by Fisher Scientific, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/lc+system/acetonitrile+grade+lc+ms/pmc13266259-46-0-12
Average 86 stars, based on 1 article reviews
lc grade acetonitrile - by Bioz Stars, 2026-11
86/100 stars

Images

Related Articles

Mass Spectrometry:

Article Title: Rapid modulation of gut microbiota composition by hypothalamic circuits in mice.
Article Snippet: .. A Dionex Ultimate 3000 RS LC system coupled to an Orbitrap mass spectrometer (Q Exactive, ThermoHESI-II Fisher Scientific) equipped with a heated electrospray ionization (HESI-II) probe was used. .. Solvents were of LC–MS grade quality (Merck).

other:

Article Title: Quantitative Multiple Fragment Monitoring with Enhanced In-Source Fragmentation/Annotation Mass Spectrometry
Article Snippet: 7290). . Reagents used in the HPLC-EISA-Q system LC-MS grade acetonitrile (Fisher Chemical, cat. no. A955–4).

Article Title: Improving Solubility and Permeability of Hesperidin through Electrospun Orange-Peel-Extract-Loaded Nanofibers.
Article Snippet: As for equipment, the LC system (Dionex Thermoline Fisher Scientific) with Chromeleon software version 7.0 was used.

Article Title: Azithromycin-Loaded Nanoparticles Incorporated in Chitosan-Based Soft Hydrogels: A Novel Approach for Dental Drug Delivery.
Article Snippet: An LC system with Chromeleon software version 7.0 (Dionex Thermoline Fisher Scientific) was used as HPLC measurement equipment.

Article Title: New non-randomised model to assess the prevalence of discriminating behaviour: a pilot study on mephedrone
Article Snippet: Qualitative analysis was carried out using a Thermoscientific liquid chromatography - tandem mass spectrometry (LC-MS/MS) system (Fisher Scientific UK Ltd, Loughborough, Leicestershire, UK).

Liquid Chromatography with Mass Spectroscopy:

Article Title: Vesicle-based cell-free synthesis of short and long unspecific peroxygenases
Article Snippet: .. Chromatographic separations in LC-MS experiments were performed on a Thermo Scientific Vanquish Flex Quaternary UHPLC system (Fisher Scientific GmbH, Waltham, MA, USA) using a Kinetex ® column (C18, 2.6 μm, 100 Å, 150 × 2.1 mm, Phenomenex, Torrance, CA, USA). .. The injection volume was 1 μL, and the column was eluted at a flow rate of 0.5 ml min −1 and 40°C with two mobile phases: A (diH 2 O, 0.1% formic acid) and B (acetonitrile, 0.1% formic acid) and the following gradient: 0 min, 10% B; 0.5 min, 10% B; 5 min, 80% B; 7 min, 80% B; 7.1 min, 10% B; 10 min, 10% B. MS spectra were obtained using the Thermo Scientific Q Exactive Focus quadrupole-Orbitrap mass spectrometer (Thermo Electron, Waltham, MA, USA) coupled with a heated electrospray ionization source in positive mode.

Article Title: Bioactive Oxylipins Profile in Marine Microalgae
Article Snippet: .. Acetonitrile (ACN, LC-MS grade), methanol (MeOH, LC-MS grade), chloroform (CHCl 3 , HPLC grade) and water that has been purified using a milliQ system (H 2 O, LC-MS grade), were all obtained from Fisher Scientific. .. Hexane (HPLC grade), absolute ethanol (EtOH, HPLC grade), formic and acetic acids (HCOOH and AcOH, HPLC grade) and butylated hydroxytoluene (BHT) were purchased from Sigma Aldrich.

High Performance Liquid Chromatography:

Article Title: Bioactive Oxylipins Profile in Marine Microalgae
Article Snippet: .. Acetonitrile (ACN, LC-MS grade), methanol (MeOH, LC-MS grade), chloroform (CHCl 3 , HPLC grade) and water that has been purified using a milliQ system (H 2 O, LC-MS grade), were all obtained from Fisher Scientific. .. Hexane (HPLC grade), absolute ethanol (EtOH, HPLC grade), formic and acetic acids (HCOOH and AcOH, HPLC grade) and butylated hydroxytoluene (BHT) were purchased from Sigma Aldrich.

Purification:

Article Title: Bioactive Oxylipins Profile in Marine Microalgae
Article Snippet: .. Acetonitrile (ACN, LC-MS grade), methanol (MeOH, LC-MS grade), chloroform (CHCl 3 , HPLC grade) and water that has been purified using a milliQ system (H 2 O, LC-MS grade), were all obtained from Fisher Scientific. .. Hexane (HPLC grade), absolute ethanol (EtOH, HPLC grade), formic and acetic acids (HCOOH and AcOH, HPLC grade) and butylated hydroxytoluene (BHT) were purchased from Sigma Aldrich.



Similar Products

86
Roche magna pure lc automated extraction system
Magna Pure Lc Automated Extraction System, supplied by Roche, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/lc+system/nct03277170-15-10-9
Average 86 stars, based on 1 article reviews
magna pure lc automated extraction system - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

90
Thermo Fisher liquid chromatography-tandem mass-spectrometry (lc-ms/ms
Liquid Chromatography Tandem Mass Spectrometry (Lc Ms/Ms, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/lc+system/nct06380387-31-10-23
Average 90 stars, based on 1 article reviews
liquid chromatography-tandem mass-spectrometry (lc-ms/ms - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

99
YMC America liquid chromatography mass spectrometry lc ms
Reaction schemes <t>and</t> <t>LC-MS</t> analysis of Pp UGTs reactions with diosgenin and pennogenin . ( a ) Biosynthesis of trillin mediated by UGT91BP2 and UGT703R1–3 through transferring glucose from UDP-glucose to the C-3 OH position of diosgenin. ( b ) Extracted ion chromatograms (EICs) of the in vitro enzyme activity assays of recombinant UGT91BP2 and UGT703R1–3 with UDP-glucose and diosgenin showing the formation of trillin, as compared to the authentic trillin standard. Control is the empty expression vector. ( c ) MS spectra of the enzymatic reaction products in hydrogen and sodium ion adducts compared to the fragmentation pattern of the trillin standard. The product molecular ions [M + H] + and [M +Na] + and the feature fragment ion [M + H − Glc] + with m / z 415.32 are marked. Of note, additional peaks observed in the diosgenin EIC ( m / z 415.32) for UGT703R1–3 might correspond to substrate isomeric impurities, in-source adducts, or minor non-enzymatic by-products; these peaks, which arose from the extracted ion flow of the substrate m / z , did not co-elute with the product, trillin , and therefore did not affect the interpretation of the product formation. ( d ) Biosynthesis of pennogenin 3- O -glucoside mediated by the UGT703R1–3 through transferring glucose from UDP-glucose to the C-3 OH position of pennogenin. ( e ) EICs of the in vitro enzyme activity assays of recombinant UGT91BP2 and UGT703R1–3 with UDP-glucose and pennogenin showing the formation of pennogenin 3- O -glucoside, compared to the control empty expression vector. ( f ) MS/MS spectra ([M + H – Glc] + and [M + H – Glc − H 2 O] + ) of the enzymatic reaction products.
Liquid Chromatography Mass Spectrometry Lc Ms, supplied by YMC America, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/lc+system/YMC-Triart+C18/pmc13123502-92-0-8
Average 99 stars, based on 1 article reviews
liquid chromatography mass spectrometry lc ms - by Bioz Stars, 2026-11
99/100 stars
  Buy from Supplier

86
Fisher Scientific lc grade acetonitrile
Reaction schemes <t>and</t> <t>LC-MS</t> analysis of Pp UGTs reactions with diosgenin and pennogenin . ( a ) Biosynthesis of trillin mediated by UGT91BP2 and UGT703R1–3 through transferring glucose from UDP-glucose to the C-3 OH position of diosgenin. ( b ) Extracted ion chromatograms (EICs) of the in vitro enzyme activity assays of recombinant UGT91BP2 and UGT703R1–3 with UDP-glucose and diosgenin showing the formation of trillin, as compared to the authentic trillin standard. Control is the empty expression vector. ( c ) MS spectra of the enzymatic reaction products in hydrogen and sodium ion adducts compared to the fragmentation pattern of the trillin standard. The product molecular ions [M + H] + and [M +Na] + and the feature fragment ion [M + H − Glc] + with m / z 415.32 are marked. Of note, additional peaks observed in the diosgenin EIC ( m / z 415.32) for UGT703R1–3 might correspond to substrate isomeric impurities, in-source adducts, or minor non-enzymatic by-products; these peaks, which arose from the extracted ion flow of the substrate m / z , did not co-elute with the product, trillin , and therefore did not affect the interpretation of the product formation. ( d ) Biosynthesis of pennogenin 3- O -glucoside mediated by the UGT703R1–3 through transferring glucose from UDP-glucose to the C-3 OH position of pennogenin. ( e ) EICs of the in vitro enzyme activity assays of recombinant UGT91BP2 and UGT703R1–3 with UDP-glucose and pennogenin showing the formation of pennogenin 3- O -glucoside, compared to the control empty expression vector. ( f ) MS/MS spectra ([M + H – Glc] + and [M + H – Glc − H 2 O] + ) of the enzymatic reaction products.
Lc Grade Acetonitrile, supplied by Fisher Scientific, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/lc+system/acetonitrile+grade+lc+ms/pmc13266259-46-0-12
Average 86 stars, based on 1 article reviews
lc grade acetonitrile - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

95
Agilent technologies preparative hplc system
Reaction schemes <t>and</t> <t>LC-MS</t> analysis of Pp UGTs reactions with diosgenin and pennogenin . ( a ) Biosynthesis of trillin mediated by UGT91BP2 and UGT703R1–3 through transferring glucose from UDP-glucose to the C-3 OH position of diosgenin. ( b ) Extracted ion chromatograms (EICs) of the in vitro enzyme activity assays of recombinant UGT91BP2 and UGT703R1–3 with UDP-glucose and diosgenin showing the formation of trillin, as compared to the authentic trillin standard. Control is the empty expression vector. ( c ) MS spectra of the enzymatic reaction products in hydrogen and sodium ion adducts compared to the fragmentation pattern of the trillin standard. The product molecular ions [M + H] + and [M +Na] + and the feature fragment ion [M + H − Glc] + with m / z 415.32 are marked. Of note, additional peaks observed in the diosgenin EIC ( m / z 415.32) for UGT703R1–3 might correspond to substrate isomeric impurities, in-source adducts, or minor non-enzymatic by-products; these peaks, which arose from the extracted ion flow of the substrate m / z , did not co-elute with the product, trillin , and therefore did not affect the interpretation of the product formation. ( d ) Biosynthesis of pennogenin 3- O -glucoside mediated by the UGT703R1–3 through transferring glucose from UDP-glucose to the C-3 OH position of pennogenin. ( e ) EICs of the in vitro enzyme activity assays of recombinant UGT91BP2 and UGT703R1–3 with UDP-glucose and pennogenin showing the formation of pennogenin 3- O -glucoside, compared to the control empty expression vector. ( f ) MS/MS spectra ([M + H – Glc] + and [M + H – Glc − H 2 O] + ) of the enzymatic reaction products.
Preparative Hplc System, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/lc+system/Bio+LC/pmc13788030-394-1-4
Average 95 stars, based on 1 article reviews
preparative hplc system - by Bioz Stars, 2026-11
95/100 stars
  Buy from Supplier

95
Agilent technologies agilent quadrupole time
Reaction schemes <t>and</t> <t>LC-MS</t> analysis of Pp UGTs reactions with diosgenin and pennogenin . ( a ) Biosynthesis of trillin mediated by UGT91BP2 and UGT703R1–3 through transferring glucose from UDP-glucose to the C-3 OH position of diosgenin. ( b ) Extracted ion chromatograms (EICs) of the in vitro enzyme activity assays of recombinant UGT91BP2 and UGT703R1–3 with UDP-glucose and diosgenin showing the formation of trillin, as compared to the authentic trillin standard. Control is the empty expression vector. ( c ) MS spectra of the enzymatic reaction products in hydrogen and sodium ion adducts compared to the fragmentation pattern of the trillin standard. The product molecular ions [M + H] + and [M +Na] + and the feature fragment ion [M + H − Glc] + with m / z 415.32 are marked. Of note, additional peaks observed in the diosgenin EIC ( m / z 415.32) for UGT703R1–3 might correspond to substrate isomeric impurities, in-source adducts, or minor non-enzymatic by-products; these peaks, which arose from the extracted ion flow of the substrate m / z , did not co-elute with the product, trillin , and therefore did not affect the interpretation of the product formation. ( d ) Biosynthesis of pennogenin 3- O -glucoside mediated by the UGT703R1–3 through transferring glucose from UDP-glucose to the C-3 OH position of pennogenin. ( e ) EICs of the in vitro enzyme activity assays of recombinant UGT91BP2 and UGT703R1–3 with UDP-glucose and pennogenin showing the formation of pennogenin 3- O -glucoside, compared to the control empty expression vector. ( f ) MS/MS spectra ([M + H – Glc] + and [M + H – Glc − H 2 O] + ) of the enzymatic reaction products.
Agilent Quadrupole Time, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/lc+system/Bio+LC/pmc13788180-401-20-20
Average 95 stars, based on 1 article reviews
agilent quadrupole time - by Bioz Stars, 2026-11
95/100 stars
  Buy from Supplier

95
Agilent technologies 1290 infinity ii lc system
Reaction schemes <t>and</t> <t>LC-MS</t> analysis of Pp UGTs reactions with diosgenin and pennogenin . ( a ) Biosynthesis of trillin mediated by UGT91BP2 and UGT703R1–3 through transferring glucose from UDP-glucose to the C-3 OH position of diosgenin. ( b ) Extracted ion chromatograms (EICs) of the in vitro enzyme activity assays of recombinant UGT91BP2 and UGT703R1–3 with UDP-glucose and diosgenin showing the formation of trillin, as compared to the authentic trillin standard. Control is the empty expression vector. ( c ) MS spectra of the enzymatic reaction products in hydrogen and sodium ion adducts compared to the fragmentation pattern of the trillin standard. The product molecular ions [M + H] + and [M +Na] + and the feature fragment ion [M + H − Glc] + with m / z 415.32 are marked. Of note, additional peaks observed in the diosgenin EIC ( m / z 415.32) for UGT703R1–3 might correspond to substrate isomeric impurities, in-source adducts, or minor non-enzymatic by-products; these peaks, which arose from the extracted ion flow of the substrate m / z , did not co-elute with the product, trillin , and therefore did not affect the interpretation of the product formation. ( d ) Biosynthesis of pennogenin 3- O -glucoside mediated by the UGT703R1–3 through transferring glucose from UDP-glucose to the C-3 OH position of pennogenin. ( e ) EICs of the in vitro enzyme activity assays of recombinant UGT91BP2 and UGT703R1–3 with UDP-glucose and pennogenin showing the formation of pennogenin 3- O -glucoside, compared to the control empty expression vector. ( f ) MS/MS spectra ([M + H – Glc] + and [M + H – Glc − H 2 O] + ) of the enzymatic reaction products.
1290 Infinity Ii Lc System, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/lc+system/Bio+LC/pmc13785784-87-7-6
Average 95 stars, based on 1 article reviews
1290 infinity ii lc system - by Bioz Stars, 2026-11
95/100 stars
  Buy from Supplier

96
Danaher Inc 4500 triple quadrupole mass spectrometer operating
Reaction schemes <t>and</t> <t>LC-MS</t> analysis of Pp UGTs reactions with diosgenin and pennogenin . ( a ) Biosynthesis of trillin mediated by UGT91BP2 and UGT703R1–3 through transferring glucose from UDP-glucose to the C-3 OH position of diosgenin. ( b ) Extracted ion chromatograms (EICs) of the in vitro enzyme activity assays of recombinant UGT91BP2 and UGT703R1–3 with UDP-glucose and diosgenin showing the formation of trillin, as compared to the authentic trillin standard. Control is the empty expression vector. ( c ) MS spectra of the enzymatic reaction products in hydrogen and sodium ion adducts compared to the fragmentation pattern of the trillin standard. The product molecular ions [M + H] + and [M +Na] + and the feature fragment ion [M + H − Glc] + with m / z 415.32 are marked. Of note, additional peaks observed in the diosgenin EIC ( m / z 415.32) for UGT703R1–3 might correspond to substrate isomeric impurities, in-source adducts, or minor non-enzymatic by-products; these peaks, which arose from the extracted ion flow of the substrate m / z , did not co-elute with the product, trillin , and therefore did not affect the interpretation of the product formation. ( d ) Biosynthesis of pennogenin 3- O -glucoside mediated by the UGT703R1–3 through transferring glucose from UDP-glucose to the C-3 OH position of pennogenin. ( e ) EICs of the in vitro enzyme activity assays of recombinant UGT91BP2 and UGT703R1–3 with UDP-glucose and pennogenin showing the formation of pennogenin 3- O -glucoside, compared to the control empty expression vector. ( f ) MS/MS spectra ([M + H – Glc] + and [M + H – Glc − H 2 O] + ) of the enzymatic reaction products.
4500 Triple Quadrupole Mass Spectrometer Operating, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/lc+system/SCIEX+Triple+Quad+4500+LC-MS%2FMS+System/pmc13784319-118-19-18
Average 96 stars, based on 1 article reviews
4500 triple quadrupole mass spectrometer operating - by Bioz Stars, 2026-11
96/100 stars
  Buy from Supplier

95
Agilent technologies peptides
Reaction schemes <t>and</t> <t>LC-MS</t> analysis of Pp UGTs reactions with diosgenin and pennogenin . ( a ) Biosynthesis of trillin mediated by UGT91BP2 and UGT703R1–3 through transferring glucose from UDP-glucose to the C-3 OH position of diosgenin. ( b ) Extracted ion chromatograms (EICs) of the in vitro enzyme activity assays of recombinant UGT91BP2 and UGT703R1–3 with UDP-glucose and diosgenin showing the formation of trillin, as compared to the authentic trillin standard. Control is the empty expression vector. ( c ) MS spectra of the enzymatic reaction products in hydrogen and sodium ion adducts compared to the fragmentation pattern of the trillin standard. The product molecular ions [M + H] + and [M +Na] + and the feature fragment ion [M + H − Glc] + with m / z 415.32 are marked. Of note, additional peaks observed in the diosgenin EIC ( m / z 415.32) for UGT703R1–3 might correspond to substrate isomeric impurities, in-source adducts, or minor non-enzymatic by-products; these peaks, which arose from the extracted ion flow of the substrate m / z , did not co-elute with the product, trillin , and therefore did not affect the interpretation of the product formation. ( d ) Biosynthesis of pennogenin 3- O -glucoside mediated by the UGT703R1–3 through transferring glucose from UDP-glucose to the C-3 OH position of pennogenin. ( e ) EICs of the in vitro enzyme activity assays of recombinant UGT91BP2 and UGT703R1–3 with UDP-glucose and pennogenin showing the formation of pennogenin 3- O -glucoside, compared to the control empty expression vector. ( f ) MS/MS spectra ([M + H – Glc] + and [M + H – Glc − H 2 O] + ) of the enzymatic reaction products.
Peptides, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/lc+system/Bio+LC/pm43045856-138-1-15
Average 95 stars, based on 1 article reviews
peptides - by Bioz Stars, 2026-11
95/100 stars
  Buy from Supplier

99
Shimadzu Corporation nexera lc 30ad uhplc
Reaction schemes <t>and</t> <t>LC-MS</t> analysis of Pp UGTs reactions with diosgenin and pennogenin . ( a ) Biosynthesis of trillin mediated by UGT91BP2 and UGT703R1–3 through transferring glucose from UDP-glucose to the C-3 OH position of diosgenin. ( b ) Extracted ion chromatograms (EICs) of the in vitro enzyme activity assays of recombinant UGT91BP2 and UGT703R1–3 with UDP-glucose and diosgenin showing the formation of trillin, as compared to the authentic trillin standard. Control is the empty expression vector. ( c ) MS spectra of the enzymatic reaction products in hydrogen and sodium ion adducts compared to the fragmentation pattern of the trillin standard. The product molecular ions [M + H] + and [M +Na] + and the feature fragment ion [M + H − Glc] + with m / z 415.32 are marked. Of note, additional peaks observed in the diosgenin EIC ( m / z 415.32) for UGT703R1–3 might correspond to substrate isomeric impurities, in-source adducts, or minor non-enzymatic by-products; these peaks, which arose from the extracted ion flow of the substrate m / z , did not co-elute with the product, trillin , and therefore did not affect the interpretation of the product formation. ( d ) Biosynthesis of pennogenin 3- O -glucoside mediated by the UGT703R1–3 through transferring glucose from UDP-glucose to the C-3 OH position of pennogenin. ( e ) EICs of the in vitro enzyme activity assays of recombinant UGT91BP2 and UGT703R1–3 with UDP-glucose and pennogenin showing the formation of pennogenin 3- O -glucoside, compared to the control empty expression vector. ( f ) MS/MS spectra ([M + H – Glc] + and [M + H – Glc − H 2 O] + ) of the enzymatic reaction products.
Nexera Lc 30ad Uhplc, supplied by Shimadzu Corporation, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/lc+system/Nexera+Series/pm43045850-86-19-22
Average 99 stars, based on 1 article reviews
nexera lc 30ad uhplc - by Bioz Stars, 2026-11
99/100 stars
  Buy from Supplier

Image Search Results


Reaction schemes and LC-MS analysis of Pp UGTs reactions with diosgenin and pennogenin . ( a ) Biosynthesis of trillin mediated by UGT91BP2 and UGT703R1–3 through transferring glucose from UDP-glucose to the C-3 OH position of diosgenin. ( b ) Extracted ion chromatograms (EICs) of the in vitro enzyme activity assays of recombinant UGT91BP2 and UGT703R1–3 with UDP-glucose and diosgenin showing the formation of trillin, as compared to the authentic trillin standard. Control is the empty expression vector. ( c ) MS spectra of the enzymatic reaction products in hydrogen and sodium ion adducts compared to the fragmentation pattern of the trillin standard. The product molecular ions [M + H] + and [M +Na] + and the feature fragment ion [M + H − Glc] + with m / z 415.32 are marked. Of note, additional peaks observed in the diosgenin EIC ( m / z 415.32) for UGT703R1–3 might correspond to substrate isomeric impurities, in-source adducts, or minor non-enzymatic by-products; these peaks, which arose from the extracted ion flow of the substrate m / z , did not co-elute with the product, trillin , and therefore did not affect the interpretation of the product formation. ( d ) Biosynthesis of pennogenin 3- O -glucoside mediated by the UGT703R1–3 through transferring glucose from UDP-glucose to the C-3 OH position of pennogenin. ( e ) EICs of the in vitro enzyme activity assays of recombinant UGT91BP2 and UGT703R1–3 with UDP-glucose and pennogenin showing the formation of pennogenin 3- O -glucoside, compared to the control empty expression vector. ( f ) MS/MS spectra ([M + H – Glc] + and [M + H – Glc − H 2 O] + ) of the enzymatic reaction products.

Journal: Synthetic and Systems Biotechnology

Article Title: Functional characterization of four glycosyltransferases for biosynthesis of steroidal saponins in medicinal plant Paris polyphylla

doi: 10.1016/j.synbio.2026.04.002

Figure Lengend Snippet: Reaction schemes and LC-MS analysis of Pp UGTs reactions with diosgenin and pennogenin . ( a ) Biosynthesis of trillin mediated by UGT91BP2 and UGT703R1–3 through transferring glucose from UDP-glucose to the C-3 OH position of diosgenin. ( b ) Extracted ion chromatograms (EICs) of the in vitro enzyme activity assays of recombinant UGT91BP2 and UGT703R1–3 with UDP-glucose and diosgenin showing the formation of trillin, as compared to the authentic trillin standard. Control is the empty expression vector. ( c ) MS spectra of the enzymatic reaction products in hydrogen and sodium ion adducts compared to the fragmentation pattern of the trillin standard. The product molecular ions [M + H] + and [M +Na] + and the feature fragment ion [M + H − Glc] + with m / z 415.32 are marked. Of note, additional peaks observed in the diosgenin EIC ( m / z 415.32) for UGT703R1–3 might correspond to substrate isomeric impurities, in-source adducts, or minor non-enzymatic by-products; these peaks, which arose from the extracted ion flow of the substrate m / z , did not co-elute with the product, trillin , and therefore did not affect the interpretation of the product formation. ( d ) Biosynthesis of pennogenin 3- O -glucoside mediated by the UGT703R1–3 through transferring glucose from UDP-glucose to the C-3 OH position of pennogenin. ( e ) EICs of the in vitro enzyme activity assays of recombinant UGT91BP2 and UGT703R1–3 with UDP-glucose and pennogenin showing the formation of pennogenin 3- O -glucoside, compared to the control empty expression vector. ( f ) MS/MS spectra ([M + H – Glc] + and [M + H – Glc − H 2 O] + ) of the enzymatic reaction products.

Article Snippet: Liquid chromatography-mass spectrometry (LC-MS) was equipped with a YMC-Triart C18 column (250 mm × 4.6 mm, 5 μm), and the column temperature was set to 30 °C.

Techniques: Liquid Chromatography with Mass Spectroscopy, Transferring, In Vitro, Activity Assay, Recombinant, Control, Expressing, Plasmid Preparation, Tandem Mass Spectroscopy